This Portion of Electrical and Electronic Instrumentation contains Primary Sensing Elements and Transducers MCQs (Multiple Choice Questions and Answers) / Objective Type Questions and Answers.
1. When measuring sound level with a interferometric type transducers
- A laser beam is used with a beam splitter
- Measured variable causes a phase shift in the light propagating through optic fibre
- The phase shift is measure of sound level
- All the above.
2. While measuring liquid level with fibre optic transducers, the fibre rod or cable is cut in the form of
- Sphere
- Rectangle
- Prism
- None of the above.
3. A linear displacement transducer (digital) normally uses
- Straight binary code
- BCD
- Gray code
- Hexadecimal code
4. The tachometer encoder has
- One output
- Two output
- Three output
- All the above.
5. A tachometer encoder cab be used for measurement of displacement
- In the both the directions
- In one direction only
- Its output pulses are counted only for the forward direction
- Its output pulses are counted only for the reverse direction.
6. Incremental counters use
- One channel
- Two channel
- Two channels and some time three
- None of the above.
7. Absolute encoders are used for
- Normally one revolution
- Continuous speed
- Continuous speed in both the direction
- None of the above.
8. Moiré fringes are used for measurement of rotary displacement along with
- Only contact type encoders
- Only optical type encoders
- Both optical type and contact encoders
- None of the above.
9. The resolution of 8 bit shift encoder is
- 360°/27
- 360°/29
- 360°/28
- None of the above.
10. Absolute encoders are used where
- Fast varying signals are not used
- When position data is to be recovered even alter a temporary power outage
- Transient noise can be tolerated as it causes only transient disturbance.
- All the above.
11. Capacitive transducers have the advantages of
- very high input impedance
- very high input impedance, excellent frequency response, high sensitivity and not being affected by stay magnetic fields
- both (a) and (b)
- none of the above
12. The transducer that converts measurand into the form of pulse is called the _______ transducers.
- digital
- active
- analog
- pulse
13. A ______ is commonly used for the measurement of temperature
- photodiode
- strain gauge
- piezocrystal
- thermistor
14. LVDT windings are wound on
- copper
- ferrite
- aluminium
- steel sheets (laminated)
15. The strain gauges should have low
- resistance temperature coefficient
- resistance
- gauge factor
- all of the above
16. Which of the following devices can measure pressure directly?
- Bourdon tube
- Rotometer
- Both (a) and (b)
- Neither (a) nor (b)
17. The lower limit of useful working range of a transducer is determined by
- transducer error and noise
- minimum useful input level
- dynamic response
- cross-sensitivity
18. Self-generating type of transducers are
- Inverse
- active
- passive
- secondary
19. The sensitivity factor of strain gauge is normally of the order of
- 1 to 1.5
- 1.5 to 2.0
- 0.5 to 1
- 5 to 10
20. A pair of active transducers is
- thermocouple, thermistors
- thermistors, solar cell
- solar cell, LVDT
- thermocouple, solar cell
21. The transducers that convert the input signal into the output signal, which is a continuous function of time, are known as
- analog
- digital
- active
- passive
22. A strain gauge with a resistance of 250 Ω undergoes a change of 0.150 Ω during a test. The strain is 1.5 × 10-4. Then the gauge factor is
- 4
- 3
- 2
- 100
23. Consider the following transducers:
- LVDT
- Piezoelectric
- Thermocouple
- Photovoltaic cell
- Strain gauge
- 2, 3 and 5
- 1, 3 and 4
- 1, 2 and 5
- 2, 3 and 4
24. LVDT can be used for
- angular velocity measurement of a column
- load measurement
- vibration measurement
- force measurement in a beam
25. Thermocouples
- require reference junction compensation
- are most commonly used as temperature transducer
- have an ion output voltage level
- all of the above
26. A thermocouple temperature indicator with reference junction at room temperature has a time constant of 1 s. It is dipped in a hot bath of 120°C. If the room temperature is 20°C, after 1 s the thermocouple type temperature indicator will read
- 63.2°C
- 100°C
- 120°C
- 140°C